Acson G6 Spécifications

Naviguer en ligne ou télécharger Spécifications pour Télécommandes Acson G6. Acson G6 Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 65
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Ceiling Cassette
Split Systems
Manual No: TMA-ACK-A-1230B
ACK20 A/AR
ACK25 A/AR
ACK30 A/AR
ACK40 A/AR
ACK50 A/AR
ACK15 B/BR
ACK20 B/BR
ACK25 B/BR
ACK30 B/BR
Models:
Vue de la page 0
1 2 3 4 5 6 ... 64 65

Résumé du contenu

Page 1 - Split Systems

Ceiling CassetteSplit SystemsManual No: TMA-ACK-A-1230BACK20 A/ARACK25 A/ARACK30 A/ARACK40 A/ARACK50 A/ARACK15 B/BRACK20 B/BRACK25 B/B

Page 2 - CONTENTS

91/1 Octave A-weighed sound pressure level (dBA), ref 20µPa125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz Ave.ModelH M L H M L H M L H M L H M L H M L H M L H

Page 3 - 1. SPECIAL FEATURES

10Ensure the operating temperature is in allowable range.Cooling onlyCoolingHeat pumpHeating Cooling4. OPERATING RANGEThe use of your air conditionero

Page 4 - 2. SPECIFICATIONS

11MODEL : ACK20A / ALC20BIndoor DB Indoor WB Capacity Outdoor DB, ° C° C ° C kW 19.4 25 30 35 40 4626.7 13.9 TC5.353 5.146 4.961 4.776 4.592 4.370SC5.

Page 5 - CEILING CASSETTE (HEAT PUMP)

12MODEL : ACK40A / ALC40CIndoor DB Indoor WB Capacity Outdoor DB, ° C° C ° C kW 19.4 25 30 35 40 4626.7 13.9 TC11.260 10.642 10.090 9.538 8.986 8.324S

Page 6

13INDOOR UNITACK 20/ 25/ 30/ 40/ 50A/ARACK 15/ 20/ 25/ 30 B/BRBACDEFHJIGKMODELA B C D E F G H I J KACK-A (All model)820 820 363 335 28 930 930 624 622

Page 7 - R407C / TXV (OUTDOOR)

14OUTDOOR UNITALC 30/ 40/ 50C/CRA4LC 30/ 40/ 50 C/CR

Page 8

15INDOOR UNIT (COOLING ONLY)MODEL : ACK 20/ 25A (C3A BOARD)7. WIRING DIAGRAMSOUTDOOR UNITMODEL : ALC/ A4LC 20/ 25B

Page 9

16INDOOR UNIT (COOLING ONLY)MODEL : ACK 30A (C3A BOARD)OUTDOOR UNITMODEL : ALC / A4LC 30C

Page 10 - 3. NOISE LEVEL

17INDOOR UNIT (COOLING ONLY)MODEL : ACK 40/ 50A (C3A BOARD)OUTDOOR UNITMODEL : ALC / A4LC 40/ 50C

Page 11 - 4. OPERATING RANGE

18INDOOR UNIT (HEAT PUMP)MODEL : ACK 20/ 25AR (C3A BOARD)OUTDOOR UNITMODEL : ALC / A4LC 20/ 25BR

Page 12 - 5. PERFORMANCE TABLE

11. SPECIAL FEATURES ...22. SPECIFICATIONS ...

Page 13 - MODEL : ACK50A / ALC50C

19INDOOR UNIT (HEAT PUMP)MODEL : ACK 30AR (C3A BOARD)OUTDOOR UNITMODEL : ALC / A4LC 30CR

Page 14 - 6. OUTLINES AND DIMENSIONS

20INDOOR UNIT (HEAT PUMP)MODEL : ACK 40/ 50AR (C3A BOARD)OUTDOOR UNITMODEL : ALC/A4LC 40/50CR

Page 15 - OUTDOOR UNIT

21INDOOR UNIT (COOLING ONLY)MODEL : ACK 20/25A (UNIVERSAL BOARD)OUTDOOR UNITMODEL : ALC/A4LC 20/25B

Page 16 - 7. WIRING DIAGRAMS

22INDOOR UNIT (COOLING ONLY)MODEL : ACK 30A (UNIVERSAL BOARD)OUTDOOR UNITMODEL : ALC/A4LC 30C

Page 17 - MODEL : ALC / A4LC 30C

23INDOOR UNIT (COOLING ONLY)MODEL : ACK 30A (UNIVERSAL BOARD)OUTDOOR UNITMODEL : ALC 30B

Page 18 - MODEL : ALC / A4LC 40/ 50C

24INDOOR UNIT (COOLING ONLY)MODEL : ACK 40/50A (UNIVERSAL BOARD)OUTDOOR UNITMODEL : ALC/A4LC 40/50C

Page 19 - MODEL : ALC / A4LC 20/ 25BR

25INDOOR UNIT (HEAT PUMP)MODEL : ACK 20/25AR (UNIVERSAL BOARD)OUTDOOR UNITMODEL : ALC/A4LC 20/25BR

Page 20 - MODEL : ALC / A4LC 30CR

26INDOOR UNIT (HEAT PUMP)MODEL : ACK 30AR (UNIVERSAL BOARD)OUTDOOR UNITMODEL : ALC/A4LC 30CR

Page 21 - MODEL : ALC/A4LC 40/50CR

27INDOOR UNIT (HEAT PUMP)MODEL : ACK 40/50AR (UNIVERSAL BOARD)OUTDOOR UNITMODEL : ALC/A4LC 40/50CR

Page 22 - MODEL : ALC/A4LC 20/25B

28INDOOR UNIT (COOLING ONLY )MODEL : ACK 15B (UNIVERSAL BOARD)OUTDOOR UNITMODEL : ALC15B

Page 23 - MODEL : ALC/A4LC 30C

2ULTRA SLIM NEW STYLISH DESIGN PROFILEThis unit is contemporary in design and match even the most up to date interior decor. The slim, (only 22 mmfor

Page 24 - MODEL : ALC 30B

29INDOOR UNIT (COOLING ONLY )MODEL : ACK 20/25B (UNIVERSAL BOARD)OUTDOOR UNITMODEL : ALC20/25B

Page 25 - MODEL : ALC/A4LC 40/50C

30INDOOR UNIT (COOLING ONLY )MODEL : ACK 30B (UNIVERSAL BOARD)OUTDOOR UNITMODEL : ALC30C

Page 26 - MODEL : ALC/A4LC 20/25BR

31INDOOR UNIT (COOLING ONLY )MODEL : ACK 30B (UNIVERSAL BOARD)OUTDOOR UNITMODEL : ALC 30B

Page 27 - MODEL : ALC/A4LC 30CR

32INDOOR UNIT (HEAT PUMP)MODEL : ACK 15BR (UNIVERSAL BOARD)OUTDOOR UNITMODEL : ALC 15BR

Page 28

33INDOOR UNIT (HEAT PUMP)MODEL : ACK 20/ 25BR (UNIVERSAL BOARD)OUTDOOR UNITMODEL : ALC 20/ 25BR

Page 29 - MODEL : ALC15B

34INDOOR UNIT (HEAT PUMP)MODEL : ACK 30BR (UNIVERSAL BOARD)OUTDOOR UNITMODEL : ALC 30CR

Page 30 - MODEL : ALC20/25B

35ATTACHMENT60HZ OUTDOOR UNITMODEL : ALC 30C (COOLING ONLY)60HZ / 1 PHASE / 208 ~230VMODEL : ALC 40/50C (COOLING ONLY)60HZ / 3 PHASE / 200 ~230VMODEL

Page 31 - MODEL : ALC30C

363 PHASE FOR 2 & 3 HP OUTDOOR UNITMODEL : ALC 20/25B (COOLING ONLY)3 PHASE / 50 HZ / 380 ~ 415VMODEL : ALC 30C (COOLING ONLY)3 PHASE / 50 HZ / 38

Page 32

37MODEL : ALC 20/25BR (HEAT PUMP)3 PHASE / 50HZ / 380 ~ 415VMODEL : ALC 30CR (HEAT PUMP)3 PHASE / 50HZ / 380 ~ 415V

Page 33 - MODEL : ALC 15BR

38HIGH AMBIENT UNITOUTDOOR UNITMODEL : ALC 20/25B (COOLING ONLY)50HZ / 1 PHASE / 220 – 240V, 60HZ / 1 PHASE / 208 – 230VOUTDOOR UNITMODEL : ALC 30C (C

Page 34 - MODEL : ALC 20/ 25BR

3 CEILING CASSETTE (COOLING ONLY)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TE

Page 35 - MODEL : ALC 30CR

39OUTDOOR UNITMODEL : ALC 20/25BR (HEAT PUMP)50HZ / 1 PHASE / 220 – 240VOUTDOOR UNITMODEL : ALC 30CR50HZ / 1 PHASE / 220 – 240V, 60 HZ / 1 PHASE / 220

Page 36

40LOW AMBIENT UNIT (OPTIONAL)OUTDOOR UNITMODEL : ALC 10B / 15B (50HZ)OUTDOOR UNITMODEL : ALC 20B / 25B (50HZ)

Page 37 - 3 PHASE / 50 HZ / 380 ~ 415V

41LOW AMBIENT UNITOUTDOOR UNITMODEL : ALC 10/15BR50HZ / 1 PHASE / 220 – 240VOUTDOOR UNITMODEL : ALC 20BR50HZ / 1 PHASE / 220 – 240VOUTDOOR UNITMODEL :

Page 38 - MODEL : ALC 30CR (HEAT PUMP)

42Special precautions when dealing with refrigerant R407C unit1) WHAT IS NEW REFRIGERANT R407C?R407C is a zeotropic refrigerant mixture which has zero

Page 39

43c) Ensure that the compressor is not expose to open air for more than the recommended time specifiedby its manufacturer (typically less than 10 minu

Page 40

44890.0 mm (ceiling board opening)790.0 mm (hanging rod)890.0 mm (ceiling opening)620.5 mm (hanging rod)PipingDirectionUnit size 820.0 mmUnit size 820

Page 41 - MODEL : ALC 20B / 25B (50HZ)

45Indoor Unit35.0 mmCeilingBoardUNIT HANGINGACK-A ACK-B• Confirm the pitch of the hanging rod is 790.0mm X 620.5mm (ACK-A) / 600.0mm x 582.0 mm (ACK-B

Page 42

46PANEL INSTALLATION• The front panel can only be fitted in one direction, follow the piping direction. (Follow piping arrow stickeron front panel).•

Page 43

47AIR INTAKE GRILLE INSTALLATION• Before installed the air intake grille, makesure the air filter is clip properly to the airintake grille.• Install t

Page 44

48Refrigerant piping is important in particular. Refrigeration cycle of the split air conditioner is realizedby the perfect piping work.PIPING LENGTH

Page 45 - Min 0.5 m

4CEILING CASSETTE (HEAT PUMP)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND

Page 46 - DRAIN TEST

49CAUTION FOR R407CAvoid prolong exposure of an opened compressor, or the internal part of refrigerant piping to moistair. The POE oil in the compress

Page 47 - PANEL INSTALLATION

50REMOTE CONTROLWhen there is infrared remote control operating signal, the signal receiver on indoor unit will made a <beep> for signalacceptan

Page 48 - OUTDOOR UNIT INSTALLATION

51WIRELESS REMOTE CONTROL (UNIVERSAL BOARD)Cooling : LED Indicator Light Display Heatpump : LED Indicator Light DisplayPOWERTIMER SLEEP HEATOperation

Page 49 - 11. REFRIGERANT PIPING WORK

52SHORT DUCT SPECIFICATION• The indoor unit is provided with air discharge and air intake "knock-out". hole for duct connection.However the

Page 50 - 12. WIRING

53SEALING MATERIAL• It is possible to seal one of the four air discharge outlet (sealing two or more air discharge outlet couldcause a malfunction).•

Page 51 - 13. INDICATOR LIGHTS

54AUTOMATIC AIR SWING• Press the button toactivate the automatic airswing function. Theswing angle ranging fromhorizontal to 25° tobottom.FAN SPEED AN

Page 52 - 4 Times every 3 sec

55SLM AC-5300 (OPTIONAL)1. “ON/OFF” switch• Press to start the air conditioner unit.• Press again to stop the unit.2. Temperature setting• Set the des

Page 53 - 14. ACCESSORY PARTS

56G8 REMOTE CONTROLLER1. Transmission source• The source where the signal will be transmitted.2. Signal Transmission indication• Blink to confirm the

Page 54 - 15. OVERALL CHECKING

57Warning: Disconnect from main supply before servicing the air conditioner.The unit is designed to give long life operation with mi

Page 55 - • Press again to stop the

58After Extended Shutdown• Inspect thoroughly and clean indoor and outdoor units.• Clean or replace air filter.• Clean condense drain line.• Clean clo

Page 56

5CEILING CASSETTE (COOLING ONLY – R407C)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING

Page 57 - G8 REMOTE CONTROLLER

5914152016193028273134343426342332243325297213181722121345610111289UNIT ( NEW HANGER )NO. PARTS DESCRIPTION NO. PARTS DESCRIPTION1 BASE PAN 18 HEXAGON

Page 58 - 18. SERVICE AND MAINTENANCE

601314171518292723303124162212626253321321234578910281119352034UNIT ( WITH OLD HANGER BRACKET )NO. PARTS DESCRIPTION NO. PARTS DESCRIPTION1 BASE PAN 1

Page 59 - 20. TROUBLESHOOTING

61PANEL ( WIRELESS REMOTE CONTROL )1296514132216202318173410712151181921NO. PART DESCRIPTION NO. PART DESCRIPTION1 FRONT PANEL 13 SWING MOTOR BRACKET2

Page 60 - 21. PARTS LIST

62PANEL (WIRED REMOTE CONTROL) 12951413616202181734107115118192122PART DESCRIPTION NO. PART DESCRIPTION1 FRONT PANEL 12 SWING MOTOR2 AIR FILTER 13 S

Page 61

63MODEL : ALC 20B / 25BNO PARTS DESCRIPTION NO PARTS DESCRIPTION1 ASSY., BACK PANEL 17 GROMMET, RUBBER2 ASSY., TOP PANEL 18 NUT, WITH WASHER3 ASSY., C

Page 62

64MODEL : ALC 30/ 40/ 50 C/ CRNO PARTS DESCRIPTION NO PARTS DESCRIPTION1 BASE PAN ASY. 8 FAN BLADE2 ACCESS / SERVICE PANEL 9 FRONT PANEL ASSY.3 CONDEN

Page 63

6CEILING CASSETTE (HEAT PUMP – R407C)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TES

Page 64 - MODEL : ALC 20B / 25B

7CEILING CASSETTE (COOLING ONLY)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED A

Page 65 - MODEL : ALC 30/ 40/ 50 C/ CR

8CEILING CASSETTE (HEAT PUMP)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND

Commentaires sur ces manuels

Pas de commentaire