Acson G18 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Télécommandes Acson G18. Chilled Water System Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Chilled Water System

Chilled Water SystemAll Product Brochure

Page 2 - About Acson International

> > F e a t u r e s> > F e a t u r e s7Memory Backup (EEPROM), Alarm Memory for Chiller and FCUWhen there is power failure occurs during o

Page 3 - PRODUCT LINE-UP

Air Cooled Mini Chiller Series Acson International offering you the range of air cooled chiller that is suitable for many applications f

Page 4

> > P r o d u c t R a n g e> > P r o d u c t R a n g eModel :AMAC 80/100/120/150 C/CRA4AC 80/100/120/150 C/CRA5ACV 100/135/210 CR Capa

Page 5

10FEATURES CompactnessThe AMAC/A4AC 20~30 C/CR is such a compact unit that it can be integrated perfectly with any architectural design, making

Page 6

> > F e a t u r e s> > F e a t u r e sChiller 0Chiller Panel 0 Chiller Panel 1Chiller 1Chiller 2Chiller CommunicationBUS11Availability Of

Page 7 - Controller

12FEATURES Chiller Control PanelThe chiller panel controller is designed to control the chiller operation. This device allows the user t

Page 8

> > F e a t u r e s> > F e a t u r e s TandemCompressors TandemCompressors TandemCompressorsHydroTech Mini Chiller13This new line of

Page 9 - Holiday Setting

14The new series of Inverter Mini Chillers are specially designed / developed to achieve better system energy saving as well as towards

Page 10 - > > F e a t u r e s

15Advantages of inverter compressor applications are:• Less Start & Stop - Frequency regulated compressor resulting in lesser in the se

Page 11

Chilled Water Fan Coil UnitsTo complement the new innovative HydroTech range of air cooled chillers, Acson International is offering an e

Page 12

Central America• Barbados •Oceania• Australia • Fiji • New Caledonia • Papua New Guinea •Middle East• Jordan • Kuwait • Lebanon • Oman • Qatar • Saudi

Page 13 - FEATURES

HydroNIM NetworkingControl System (optional)For multiple fan coil unit installation in an office, a centralised controlled operation can

Page 14

HydroTech Chilled WaterFan Coil Units RangeWall Mounted RangeAWM 05/10/15/20/25 GWAWM 301 W✓ Slim and compact✓ Wide capacity range ✓ Wide air flow ra

Page 15

Ceiling Convertible RangeRCM 20/25/40/50 DWACM 15/20/25 EWACC 10/15/20/25/30/40/50/60 CWACC 28/38 CW✓ Ceiling Convertible feature offers flexibility o

Page 16

Ceiling Concealed Range2 Pipes System:ACW 200/300/400/600/800/1000/1200 C4 Pipes System:ACW 200/300/400/600/800/1000/1200 CHADB 75/100/125/150 BW✓ Wid

Page 17

21AC8000C SeriesF E A T U R E S :A new developed thermostat series, AC 8 000 is no w a v a i l a b l e t o b e ordered as Chilled Water

Page 18 - Modular Installation

S1Mini Chiller SpecificationsAMAC20C - AMAC60C (Cooling Only, R22)HEIGHTWIDTHDEPTHMAX. WATER OPER. PRESSUREINSTALLATION PIPE CONNECITONAMAC20CR - AMAC

Page 19 - Chilled Water Fan Coil Units

S2Mini Chiller SpecificationsA4AC20C - A4AC60C (Cooling Only, R407C)A4AC20C A4AC25C A4AC30C A4AC40C A4AC50C A4AC60CBtu/h 21000 23000 27000 40000 50000

Page 20 - Control System (optional)

S3Mini Chiller SpecificationsAMAC80C - AMAC150C (Cooling Only, R22)AMAC80CAMAC100C AMAC120C AMAC150CBtu/h 78000 93000 116000 138000W 22860 27257 33998

Page 21 - Fan Coil Units Range

S4Mini Chiller SpecificationsA4AC80C - A4AC150C (Cooling Only, R407C)A4AC80CA4AC100C A4AC120C A4AC150CBtu/h 74000 88000 115000 13700W 21688 25791 3370

Page 22 - Ceiling Concealed Range

S5Mini Chiller SpecificationsA5AC20CR - A5AC55CR (Heatpump, R410A)A5AC20CR A5AC25CR A5AC30CR A5AC40CR A5AC50CR A5AC55CRBtu/h 17000 21000 26800 37500 4

Page 23 - Ducted Blower Range

Pg.S1 - Pg.S4 Pg.S5 Pg.S11 Pg.S6Pg.S5Pg.10 - Pg.11Pg.S5Pg.12 Pg.13 Pg.18 Pg.18Pg.14 - Pg.15Pg.S11Pg.18SpecificationFeaturesCapacity (Btu/hr)PRODUCT

Page 24 - AC8000C Series

S6Chilled Water Fan Coil Unit SpecificationsHIGHHEIGHTWIDTHDEPTHMODELNOMINAL TOTAL COOLING CAPACITYNOMINAL SENSIBLE COOLING CAPACITYNOMINAL TOTAL HEAT

Page 25 - Mini Chiller Specifications

S7 ACK10CW - ACK20CW (Ceilling Cassette C Series)Notes:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL U

Page 26

S8Chilled Water Fan Coil Unit SpecificationsRCM07CBW - RCM20DW (Ceilling Convertible)Btu/hWBtu/hWBtu/hWHIGH l/s / CFMHEIGHT mm/inWIDTH mm/inDEPTH mm/i

Page 27

S9Chilled Water Fan Coil Unit SpecificationsACC10CW - ACC28CW (Ceiling Concealed)ACC10CW ACC15CW ACC20CW ACC25CW ACC28CWBtu/h 9900 15000 18000 22500 2

Page 28

S10Chilled Water Fan Coil Unit SpecificationsACW200H - ACW1200H (Ceilling Concealed)SUPER HIGHHIGHMEDIUMLOWHEIGHTWIDTHDEPTHNotes:1) ALL SPECIFICATIONS

Page 29

S11Chilled Water Fan Coil Unit SpecificationsAWM07GW - AWM25GW (Wall Mount)MODELHIGHHEIGHTWIDTHDEPTHNOMINAL TOTAL COOLING CAPACITY - 1NOMINAL SENSIBL

Page 30

S12Chilled Water Fan Coil Unit SpecificationsACE15EW - ACE25EW (Ceiling Convertible)HIGHMEDIUMLOWHEIGHTWIDTHDEPTHNotes:1) ALL SPECIFICATIONS ARE SUBJE

Page 31

AP - AHS - 08Products manufactured in an ISO certified facility.This document contains the most current product information as of this printing.For th

Page 32

Pg.S7 Pg.S9Pg.S8 Pg.S8Pg.18Pg.S7Pg.18 Pg.19Pg.S10Pg.20Pg.S11Pg.20Pg.19Pg.S12Pg.19 Pg.19PRODUCT LINE-UPFor HydroNIM PC onlyHydroNIMHydroNIMHydroNIM H

Page 33

> > I n t r o d u c t i o n> > I n t r o d u c t i o nChilled Water SystemChilled Water SystemAcson International is committed to off

Page 34

> > F e a t u r e s> > F e a t u r e s chilled waterseries of products 3. Long Piping ApplicationsThe HydroTech series avoid

Page 35

Controller By adopting the HydroTech chilled water system, the comfort in residential and light commercial buildings such as offices, hospital, restau

Page 36

Alarm 1(Ch 0)Comp 1 overload01/01/0012.00amDisplay Up To 46 Types Of Chiller Fault/Alarm And 6Types Of FCU Fault/AlarmWhenever a fault occurred in

Page 37

HOLIDAY SETTINGSSet Holiday 1Holiday 1Holiday 2Holiday 3Holiday 4Holiday 5Month : 1Day : 1Duration : DisableEnergy Saving Programmable TimerThe

Commentaires sur ces manuels